Product Show

Location:Home >> Products >> Switching Power Supply Series

SCN-800

Switching Power Supply Series
Keywords:
SCN-800 switching power supply
Product Details

Model
Performance
SCN-800-12
SCN-800-13.5
SCN-800-15
SCN-800-24
SCN-800-27
SCN-800-48
DC output voltage
12V
13.5V
15V
24V
27V
48V
Output voltage tolerance(Note 2)
±1%
±1%
±1%
±1%
±1%
±1%
Rated output current
66A
59A
53A
33A
30A
16A
Output current range
0-66A
0-59A
0-53A
0-33A
0-30A
0-16A
Ripple and noise(Note 3)
150mVp-p
150mVp-p
150mVp-p
240mVp-p
240mVp-p
480mVp-p
Inlet stability(Note 4)
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
Load stability(Note 5)
±5%
±5%
±0.5%
±0.5%
±0.5%
±0.5%
DC output power
800W
800W
800W
800W
800W
800W
Efficiency
80%
81%
81%
85.5%
86.5%
87%
DC voltage adjustable range
±10%
±10%
±10%
±10%
±10%
±10%
Input voltage range
190~240VAC/47~63Hz;230V-240V
Input current
8A/230V
Surge Current
75A/230VAC
Leakage Current
<3.5mA/240VAC
Overload protection
105%~150% type:FOLDBACK cut off output reset:Automatic recovery
over-voltage protection
110%-135%
High temperature protection
≥70℃ 
temperature coefficient
±0.03%℃(0~50℃)
Start-up,rise,hold up time
1.5s,50ms,20ms
shock resistance
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes 
Withstand voltage
Input and Output internal:3KvAC,input and enclosure:1.5KvAC,output 
and enclosure:0.5KvAC
Insulation Resistance
Input and Output internal: input and enclosure,output and enclosure:
500VDC/100M Ohms
work Temperature/humidity  
-10℃~+60℃(Refer to output derating curve),20%~90%RH
storage temperature /humidity
-20℃~+85℃,10%~95%RH
Outline dimension
291*132*68mm 
Weight
2.3Kgs
Safety standards
UL1950,TUV EN60950
EMC Standards 
CISPR22(EN55022),IEC1000-42,3,4,5,6,8,11 IEC100-3-2
Note: 
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH Humidity. 
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uF capacitor circuit.
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage.
5.Load stability test: the load from 0% to 100%.other output is 60% rated load.
6. The each output can reach maximum current,but the total load can't over the maximum output power.
7. C3,4 must remove. 

 

Drawing: