Product Show

Location:Home >> Products >> Switching Power Supply Series

SCN-1200

Switching Power Supply Series
Keywords:
SCN-1200 power supply
Product Details

Model
Performance
SCN-1200-12
SCN-1200-15
SCN-1200-24
SCN1200-48
DC output voltage
12V
15V
24V
48V
Output voltage tolerance(Note 2)
±1%
±1%
±1%
±1%
Rated output current
100A
80A
50A
24A
Output current range
0-100A
0-80A
0-50A
0-24A
Ripple and noise(Note 3
360MVp-p
360mVp-p
300mVp-p
300mVp-p
Inlet stability(Note 4)
±0.5%
±0.5%
±0.5%
±0.5%
Load stability(Note 5)
±0.5%
±0.5%
±0.5%
±0.5%
DC output power
1200W
1200W
1200W
960W
Efficiency
83%
85%
85%
87%
DC voltage adjustable range
12-15V
13.5-18V
20-26.4V
41-56V
Input voltage range
190V-240VAC  47-63Hz
Input current
7A/230VAC
Surge Current
50A230VAC
Leakage Current
<3.5mA/240VAC
Overload protection
105%-135%  type:pulsing hiccup shutdown Reset:auto recovery
over-voltage protection
13.8-16.2V
15.5-18.2V
18-21V
27.6-32.4V
31-36.5V
  57.6-67.2V
High temperature protection
≥70℃ Cut off output
temperature coefficient
±0.03%℃(0~50℃)
Start-up,rise,hold up time
1.5ms,50ms,20ms
shock resistance
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes
Withstand voltage
Input and Output internal:3KvAC,input and enclosure:1.5KvAC,
output and enclosure:0.5KvAC
Insulation Resistance
Input and Output internal: input and enclosure,output and 
enclosure:500VDC/100M/Ohms
work Temperature/humidity  
-10℃~+50℃(Refer to output derating curve),20%~90%RH
storage temperature /humidity
-20℃~+85℃,10%~95%RH
Outline dimension
291*132*132mm
Weight
4.5Kgs
Safety standards
Satisfy UL1950
EMC Standards  
CISPR22(ENC55022),IEC1000-4,2,3,4,5,6,8,11 IEC1000-3-2
Note: 
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH Humidity. 
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uFcapacitor circuit. 
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage. 
5.Load stability test: the load from 0% to 100%.Others output is 60% rated load.
6.Each output can reach max current,but the total load can't over the max output power.
7.C3,4 must remove.  

 

Drawing: