Product Show

Location:Home >> Products >> Switching Power Supply Series

D-30

Switching Power Supply Series
Keywords:
30w dual output power supply
Product Details

 

Model
Performance
D-30A
D-30B
CH1
CH2
CH1
CH2
DC output voltage
5V
12V
5V
24V
Output voltage tolerance(Note 2)
±2%
+3 ,-7%
±2%
+3,-5%
Rated output current
4A
1A
2.2A
1A
Output current range
0.5-4A
0.1-1A
0.5-4A
0.1-1A
Ripple and noise(Note 3)
50mVp-p
100mVp-p
50mVp-p
100mVp-p
Inlet stability(Note 4)
±0.5%
±1%
±0.5%
±1%
Load stability(Note 5)
±0.5%
±4%
±0.5%
±4%
DC output power
32W
35W
Efficiency
72%
74%
DC voltage adjustable 
CH1+10,-5%
CH1+10,-5%
Input voltage range
85~132VAC/170~264VAC;selected by switch47~63Hz;240-370VDC
Input current
0.8A/115V 0.45A/230V
Surge Current
Cold-start current 18A/115V 36A/230V
Leakage Current
<0.5mA/240VAC
Overload protection
105%~150% type:pulsing hiccup shutdown Reset:Automatic recovery
over-voltage protection
……
High temperature protection
……
temperature coefficient
±0.03%℃(0~50℃) ON+5V OUTPUT
Start-up,rise,hold up time
200ms,50ms,30ms
shock resistance
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes
Withstand voltage
Input and Output internal:1.5KvAC,input and enclosure:1.5KvAC,
output and enclosure:0.5KvAC
Insulation Resistance
Input and Output internal: input and enclosure,output and enclosure:
500VDC/100M/Ohms
work Temperature/humidity  
-10℃~+60℃(Refer to output derating curve),20%~90%RH
storage temperature /humidity
-20℃~+85℃,10%~95RH
Outline dimension
129*98*38mm
Weight
0.4Kgs
Safety standards
Satisfy UL1012  REQUIREMENT(NOT QPPLY FOR THE MARK)
EMC Standards 
Satisfy FCC PART15 J CONDUCT 10N CLASS A
Note: 
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH Humidity. 
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uFcapacitor circuit.
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage.
5.Load stability test: the load from 0% to 100%.Others output is 60% rated load.
6.Each output can reach max current,but the total load can't over the max output power.

 

Drawing: