Product Show

Location:Home >> Products >> Switching Power Supply Series

D-60

Switching Power Supply Series
Keywords:
D-60 switching power supply
Product Details

Model
Performance
D-60A
D-60B
CH1
CH2
CH1
CH2
DC output voltage
5V
12V
5V
24V
Output voltage tolerance(Note 2)
±2%
±6%
±2%
±5%
Rated output current
4A
3A
3A
1.8A
Output current range
0.3-6A
0.2-4A
0.3-6A
0.2-2.2A
Ripple and noise(Note 3)
75mVp-p
150mVp-p
75mVp-p
150mVp-p
Inlet stability(Note 4)
±0.5%
±1%
±0.5%
±0.5%
Load stability(Note 5)
±0.5%
±4%
±0.5%
±4%
DC output power
56W
58W
Efficiency
73%
76%
DC voltage adjustable range
CH1+10,-5%
CH1+10,-5%
Input voltage range
85~264VAC 47~63Hz;120-370VDC
Input current
2A/115V 1A/230V
Surge Current
Cold-start current 30A/115V 60A/230V
Leakage Current
<1mA/240VAC
Overload protection
105%~150% type:PULSING HICCUP SHUTDOWN reset:Automatic recovery
over-voltage protection
CH1:5.75~6.75V
High temperature protection
……
temperature coefficient
±0.03%℃(0~50℃) ON+5V OUTPUT
Start-up,rise,hold up time
800ms,50ms,10ms/115VAC 300ms,50ms,80ms/230VAC
shock resistance
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes 
Withstand voltage 
Input and Output internal:3KvAC,input and enclosure:1.5KvAC,
output and enclosure:0.5KvAC
Insulation Resistance
Input and Output internal: input and enclosure,output and 
enclosure:500VDC/100M Ohms
work Temperature/humidity 
-10℃~+60℃,20%~90%RH
storage temperature /humidity
-20℃~+85℃,10%~95%RH
Outline dimension
159*97*38mm
Weight
0.55Kgs
Safety standards
Satisfy UL1012 TUV(En60950) , IEC950 certificate
EMC Standards 
CISPR22(EN55022) CLASS B,IEC801-2,3,4 IEC555-2
Note: 
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH Humidity.
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uF capacitor circuit. 
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage.
5.Load stability test: the load from 0% to 100%.other output is 60% rated load
6.The each output can reach maximum current,but the total load can't over the maximum output power.
7.C2,3,6 must remove  

 

Drawing:

 

Similar Model Display: