Product Show

Location:Home >> Products >> Switching Power Supply Series

T-30

Switching Power Supply Series
Keywords:
T-30 triple output power supplies
Product Details

Model
Performance
T-30A
T-30B
CH1
CH2
CH3
CH1
CH2
CH3
DC output voltage
5V
12V
-5V
5V
12V
-12V
Output voltage tolerance(Note 2)
±2%
+2,-6%
+2,10%
±2%
+2,-6%
±6%
Rated output current
3A
1A
0.5A
3A
1A
0.5A
Output current range
0.5-3A
0.1-1A
0.1-0.5A
0.5-3A
0.1-1A
0.1-0.5A
Ripple and noise(Note 3)
50mVp-p
100mVp-p
50mVp-p
50mVp-p
100mVp-p
100mVp-p
Inlet stability(Note 4)
±0.5%
±1%
±1%
±0.5%
±1%
±1%
Load stability(Note 5)
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
DC output power
30W
33W
Efficiency
70%
72%
DC voltage adjustable range
CH1+10,-5%
CH1+10,-5%
Input voltage range
85~132VAC/170~264VAC  selected by switch
47~63Hz;240~370VDC
Input current
0.8A/115V 0.45A/230V
Surge Current
Cold-start current 18A/115V 36A/230V
Leakage Current
<0.5mA/240VAC
Overload protection
105%~150% type:pulsing hiccup shutdown Reset:Automatic recovery 
over-voltage protection
……
High temperature protection
……
temperature coefficient
±0.03%℃(0~50℃) ON+5V OUTPUT
Start-up,rise,hold up time
200ms,100ms,30ms
shock resistance
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes
Withstand voltage
Input and Output internal:1.5KvAC,input and enclosure:1.5KvAC,
output and enclosure:0.5KvAC
Insulation Resistance
Input and Output internal: input and enclosure,output and enclosure:
500VDC/100M Ohms
work Temperature/humidity 
-10℃~+60℃(Refer to output derating curve),20%~90%RH
storage temperature /humidity
-20℃~+85℃,10%~95%RH
Outline dimension
159*97*38mm CASE:903
Weight
0.4Kgs
Safety standards
Satisfy UL1012  REQUIREMENT    (NOT QPPLY FOR THE MARK)
EMC Standards 
Satisfy FCC PART15 J CONDUCT 10N CLASS A
Note: 
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH Humidity. 
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uFcapacitor circuit. 
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage. 
5.Load stability test: the load from 0% to 100%.Others output is 60% rated load.
6.Each output can reach max current,but the total load can't over the max output power.
7.C2,3,6 must remove    

 

Drawing: