Product Show

Location:Home >> Products >> Switching Power Supply Series

T-50

Switching Power Supply Series
Keywords:
T-50 switching power supply
Product Details

Model
Performance
T-50A
T-50B    
T-50C    
 T-50D
CH1
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
CH1
CH2
CH3
DC output voltage
5V
12V
-5V
5V
12V
-12V
5V
15V
-15V
5V
12V
24V
Output voltage tolerance(Note 2)
±2%
±5%
±5%
±2%
±5%
±5%
±2%
±5%
±5%
±2%
±6%
±6%
Rated output current
7A
1A
1A
5A
1A
1A
4A
1A
1A
3A
1A
1A
Output current range
0.6-7A
0.2-1A
0.2-1A
0.6-5A
0.2-1A
0.2-1A
0.6-4A
0.2-1A
0.2-1A
0.6-4A
0.2-1.2A
0.2-1.2A
Ripple and noise(Note 3)
100mV
100mV
100mV
100mV
100mV
100mV
100mV
100mV
100mV
50mV
120mV
120mV
Inlet stability(Note 4)
±0.5%
±0.5%
±0.5
±0.5%
±0.5%
±0.5
±0.5%
±0.5%
±0.5
±0.5%
±1%
±1%
Load stability(Note 5)
±1%
±4%
±4%
±1%
±4%
±4%
±1%
±4%
±4%
±1%
±5%
±5%
DC output power
52W
49W
50W
51W
Efficiency
66%
69%
71%
72%
DC voltage adjustable range
CH1+10,-5%
CH1+10,-5%
CH1+10,-5%
CH1+10,-5%
Input voltage range
85~132VAC/170~264VAC selected by switch 47~63Hz;240~370VDC
Input current
1.6A/115V 0.8A/230V
Surge Current
Cold-start current  20A/115V 40A/230V
Leakage Current
<0.5mA/240VAC
Overload protection
105%~150% type:PULSING HICCUP SHUTDOWN reset:Automatic recovery
over-voltage protection
--------------------
High temperature protection
 --------------
temperature coefficient
±0.03%℃(0~50℃) ON+5V OUTPUT
Start-up,rise,hold up time
200ms,50ms,16ms
shock resistance
10~500Hz,2G  10min./1circle,Period for 60min.,Each axes
Withstand voltage
Input and Output internal:1.5KvAC,input and enclosure:1.5KvAC,
output and enclosure:0.5KvAC
Insulation Resistance
Input and Output internal: input and enclosure,output and enclosure:
500VDC/100M Ohms
work Temperature/humidity
-10℃~+60℃(Refer to output derating curve),20%~90%RH
storage temperature /humidity
-20℃~+85℃,10%~95%RH
Outline dimension
159*97*38mm  CASE:901
Weight
0.54Kgs
Safety standards
Satisfy UL1012 REQUIREMENT  (NOT QPPLY FOR THE MARK)
EMC Standards 
……
Note: 
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH Humidity. 
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uFcapacitor circuit. 
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage. 
5.Load stability test: the load from 0% to 100%.Others output is 60% rated load.
6.Each output can reach max current,but the total load can't over the max output power.

 

Drawing: