Product Show

Location:Home >> Products >> Switching Power Supply Series

Q-60

Switching Power Supply Series
Keywords:
60w quad output switching power supply
Product Details

Model
Performance
CH1
CH2
CH3
CH4
DC output voltage
5V
12V
-5V
-12V
Output voltage tolerance(Note 2)
±2%
±6%
±5%
±5%
Rated output current
5.5A
2A
0.5A
0.5A
Output current range
0.5-8A
0.1-3A
0-1A
0-1A
Ripple and noise(Note 3)
100mVp-p
120mVp-p
100mVp-p
120mVp-p
Inlet stability(Note 4)
±0.5%
±1%
±0.5%
±0.5%
Load stability(Note 5)
±0.5%
±4%
±1%
±1%
DC output power
60W
Efficiency
70%
DC voltage adjustable range
CH1:+10,-5%
Input voltage range
85~264VAC/47~63VAC;120~370VDC
Input current
1.3A/115V 0.8A/230V
Surge Current
Cold-start current 18A/115V 36A/230V
Leakage Current
<1mA/240VAC
Overload protection
105%~150% type:pulsing hiccup shutdown Reset:Automatic recovery
over-voltage protection
CH1:5.75~6.75V
High temperature protection
……
temperature coefficient
±0.03%℃(0~50℃)
Start-up,rise,hold up time
1.6s,20ms,12ms/115VAC 800ms,20ms,60ms/230VAC
shock resistance
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes
Withstand voltage
Input and Output internal:3KvAC,input and enclosure:1.5KvAC,
output and enclosure:0.5KvAC
Insulation Resistance
Input and Output internal: input and enclosure,output and 
enclosure:500VDC/100M/Ohms
work Temperature/humidity  
-10℃~+60℃(Refer to output derating curve),20%~90%RH
storage temperature /humidity
-20℃~+85℃,10%~95RH
Outline dimension
159*97*38mm  CASE:901
Weight
0.83Kgs
Safety standards
UL1950 certificate
EMC Standards 
CISPR22(according to EN5502),IEC801-2,3,4,IEC55-2 certificate
Note: 
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH Humidity. 
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uFcapacitor circuit.
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage.
5.Load stability test: the load from 0% to 100%.
6.Each output can reach max current,but the total load can't over the max output power.
7.C2,3,6 must remove   

 

Drawing: