Model  Performance
S-15-5
S-15-12
S-15-24
DC output voltage
5V
12V
24V
Output voltage tolerance(Note 2)
±2%
±1%
±1%
Rated output current
3A
1.3A
0.7A
Output current range
0-3A
0-1.3A
0-0.7A
Ripple and noise(Note 3)
50mVp-p
50mVp-p
100mVp-p
Inlet stability(Note 4)
±0.5%
±0.5%
±0.5%
Load stability(Note 5)
±1%
±0.5%
±0.5%
DC output power
15W
15.6W
16.8W
Efficiency
65%
68%
72%
DC voltage adjustable range
±10,-5%
±10%
±10%
Input voltage range
85~132VAC/170~264VAC selected by switch
 47~63Hz240~370VDC
Input current
0.5A/115V 0.25A/230V
Surge Current
Cold-start current 15A/115V 30A/230V
Leakage Current
<0.5mA/240VAC
Overload protection
105%~150%type:pulsing hiccup shutdown Reset:auto recovery
over-voltage protection
……
High temperature protection
……
temperature coefficient
±0.02%℃(0~50℃)
Start-up,rise,hold up time
200ms,100ms,30ms
shock resistance
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes
Withstand voltage
Input and Output internal:1.5KvAC,input and enclosure:1.5KvAC,output and enclosure:0.5KvAC
Insulation Resistance
Input and Output internal: input and enclosure,output and enclosure:500VDC/100M/Ohms
work temperature/humidity    
-10℃~+60℃(Refer to output derating curve),20%~90%RH
storage temperature /humidity
-20℃~+85℃,10%~95RH
Outline dimension
99*97*35mm CASE:905
Weight
0.3Kgs
Safety standards
Satisfy the requires of UL1012
EMC Standards
Satisfy the clause CLASS B of FCC PART15J
Note
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH.Humidity.
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uFcapacitor circuit.
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage.
5.Load stability test: the load from 0% to 100%.