Product Show

Location:Home >> Products >> Switching Power Supply Series

S-25

Switching Power Supply Series
Keywords:
S-25 power supply
Product Details

 

Model 
Performance 
S-25-5
S-25-12
S-25-15
S-25-24
DC output voltage  
5V
12V
15V
24V
Output voltage tolerance(Note 2) 
±2%
±1%
±1%
±1%
Rated output current 
5A
2.1A
1.7A
1.1A
Output current range 
0-5A
0-2.1A
0-1.7A
0-1.1A
Ripple and noise(Note 3) 
50mVp-p
100mVp-p
100mVp-p
100mVp-p
Inlet stability(Note 4) 
±0.5%
±0.5%
±0.5%
±0.5%
Load stability(Note 5) 
±1%
±0.5%
±0.3%
±0.2%
DC output power 
25W
25.2W
25.5W
26.4W
Efficiency 
72%/115VAC
76%/115VAC
77%/115VAC
80%/115VAC
DC voltage adjustable range 
+10,-5%
±10%
±10%
±10%
Input voltage range 
85~264VAC/47~63VAC; selected by switch
 47~63Hz 240~370VDC
Input current 
0.6A/115V 0.35A/230V
Surge Current 
Cold Start current 15A/115V 30A/230V 
Leakage Current 
<0.75mA/240VAC
Overload protection 
105%~150% type:pulsing hiccup shutdown Reset:Automatic recovery
over-voltage protection 
115%~135%
High temperature protection 
……
temperature coefficient 
±0.03%℃(0~50℃)
Start-up,rise,hold up time 
800ms,50ms,20ms/115VAC 300ms,50ms,80ms/230VAC
shock resistance
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes
Withstand voltage 
Input and Output internal:3KvAC,input and enclosure:1.5KvAC,
output and enclosure:0.5KvAC
Insulation Resistance
Input and Output internal: input and enclosure,output and enclosure:
500VDC/100M Ohms
work Temperature/humidity 
-10℃~+60℃(Refer to output derating curve),20%~90%RH
storage temperature /humidity 
-20℃~+85℃,10%~95%RH
Outline dimension 
99*97*35mm CASE:905
Weight 
0.35Kgs
Safety standards 
Satisfy the certificate of UL1012,TUV EN60950(IEC950,UL1950)
EMC Standards 
CISPR22(EN55022)IEC801-2,3,4,IEC555-2 certificate
Note: 
1 The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH. Humidity.
2 Tolerance: includes set up tolerance, line stability and load stability (Note 5). 
3. the ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uF capacitor circuit. 
4. the incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage. 
5.load stability test: the load from 0% to 100%.                                                             

 

 

Drawing: