Model 
Performance 
S-35-5
S-35-12
S-35-15
S-35-24
DC output voltage 
5V
12V
15V
24V
Output voltage tolerance(Note 2) 
±2%
±1%
±1%
±1%
Rated output current
7A
3A
2.4A
1.5A
Output current range 
0-7A
0-3A
0-2.4A
0-1.5A
Ripple and noise(Note 3) 
75mVp-p
100mVp-p
100mVp-p
100mVp-p
Inlet stability(Note 4) 
±0.5%
±0.5%
±0.5%
±0.5%
Load stability(Note 5) 
±1%
±0.5%
±0.5%
±0.5%
DC output power 
35W
36W
36W
36W
Efficiency 
70%
76%
78%
78%
DC voltage adjustable range 
±10,-5%
±10%
±10%
±10%
Input voltage range 
85~132VAC/170~264VAC selected by switch
 47~63Hz240~370VDC
Input current 
0.8A/115V 0.45A/230V
Surge Current 
Cold-start current 18A/115V 36A/230V
Leakage Current 
< 0.5mA/240VAC
Overload protection 
105%~150%type:pulsing hiccup shutdown Reset:Automatic recovery
Over-voltage protection 
……
High temperature protection 
……
Temperature coefficient 
±0.03%℃(0~50℃)
Start-up,rise,hold up time 
200ms,100ms,30ms
Shock resistance 
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes 
Withstand voltage 
Input and Output internal:1.5KvAC,input and enclosure:1.5KvAC,output and enclosure:0.5KvAC
Insulation Resistance 
Input and Output internal: input and enclosure,output and enclosure:500VDC/100M Ohms
work Temperature/humidity 
-10℃~+60℃(refer to output derating curve)20%~90%RH
storage temperature /humidity 
-20℃~+85℃,10%~95RH
Outline dimension 
129*98*38mm  CASE:903
Weight 
0.4Kgs
Safety standards 
Satisfy the requires of UL1012(NOT APPLY FOR THE MARK)  
EMC Standards 
Satisfy FCC PART15JCONDUCTION CLASS B
Note: 
1. The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH.Humidity. 
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uFcapacitor circuit. 
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage. 
5.Load stability test: the load from 0% to 100%.

 