Product Show

Location:Home >> Products >> Switching Power Supply Series

S-50

Switching Power Supply Series
Keywords:
50w switch power supply
Product Details

Model 
Performance 
S-50-5
S-50-12
S-50-15
S-50-24
DC output voltage 
5V
12V
15V
24V
Output voltage tolerance(Note 2) 
±2%
±1%
±1%
±1%
Rated output current 
10A
4.2A
3.4A
2.1A
Output current range 
0-10A
0-4.2A
0-3.4A
0-2.1A
Ripple and noise(Note 3)
75mVp-p
100mVp-p
100mVp-p
100mVp-p
Inlet stability(Note 4) 
±0.5%
±0.5%
±0.5%
±0.5%
Load stability(Note 5) 
±1%
±0.5%
±0.5%
±0.5%
DC output power 
50W
50.4W
51W
50.4W
Efficiency 
71%
78%
78%
82%
DC voltage adjustable range 
±10,-5%
±10%
±10%
±10%
Input voltage range 
85~132VAC/170~264VAC selected by switch 47~63Hz;240~370VDC
Input current 
1.3A/115V 0.65A/230V
Surge Current 
Cold-start current 18A/115V 36A/230V 
Leakage Current 
< 0.5mA/240VAC
Overload protection 
105%~150%type:pulsing hiccup shutdown Reset:Automatic recovery
over-voltage protection 
……
High temperature protection
……
temperature coefficient 
±0.03%℃(0~50℃)
Start-up,rise,hold up time 
200ms,100ms,30ms
shock resistance 
10~500Hz,2G 10min./1circle,Period for 60min,Each axes 
Withstand voltage 
Input and Output internal:1.5KvAC,input and enclosure:1.5KvAC,
output and enclosure:0.5KvAC
Insulation Resistance 
Input and Output internal: input and enclosure,output and 
enclosure:500VDC/100M Ohms
work Temperature/humidity 
-10℃~+60℃ (Refer to output derating curve),20%~90%RH
storage temperature /humidity 
-20℃~+85℃,10%~95%RH
Outline dimension 
159*97*38mm
Weight 
0.5Kgs
Safety standards 
Satisfy the requires of UL1012(NOT APPLY FOR THE MARK)    
EMC Standards 
……
Note: 
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH. Humidity. 
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uF capacitor circuit. 
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage. 
5.Load stability test: the load from 0% to 100%.
 

 