Product Show

Location:Home >> Products >> Switching Power Supply Series

S-75

Switching Power Supply Series
Keywords:
75w switch power supply
Product Details

Model
Performance 
S-75-5
S-75-12
S-75-15
S-75-24
DC output voltage 
5V
12V
15V
24V
Output voltage tolerance(Note 2) 
±2%
±1%
±1%
±1%
Rated output current 
15A
6.3A
5A
3.2A
Output current range 
0-10A
0-4.2A
0-3.4A
0-2.1A
Ripple and noise(Note 3) 
70mVp-p
100mVp-p
100mVp-p
100mVp-p
Inlet stability(Note 4) 
±0.5%
±0.5%
±0.5%
±0.5%
Load stability(Note 5) 
±1%
±0.5%
±0.5%
±0.5%
DC output power 
75W
75.6W
75W
76.8W
Efficiency 
71%
78%
78%
82%
DC voltage adjustable range 
+10,-5%
±10%
±10%
±10%
Input voltage range 
85~132VAC/47~63Hz;170~264VAC choose by switch 47-63Hz;240-370VDC
Input current 
1.6A/115V 0.8A/230V
Surge Current
Cold-start current 18A/115V 36A/230V
Leakage Current 
<0.5mA/240VAC
Overload protection 
105%~150% type:pulsing hiccup shutdown reset:Automatic recovery 105%~150% 
over-voltage protection 
105%~150%
High temperature protection 
……
temperature coefficient 
±0.03%℃(0~50℃)
Start-up,rise,hold up time 
200ms,100ms,30ms
shock resistance 
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes 
Withstand voltage  
Input and Output internal:1.5KvAC,input and enclosure:
1.5KvAC,output and enclosure:0.5KvAC
Insulation Resistance 
Input and Output internal: input and enclosure,output and 
enclosure:500VDC/100M Ohms
work Temperature/humidity   
-10℃~+60℃(Refer to output derating curve),20%~90%RH
storage temperature /humidity 
-20℃~+85℃,10%~95%RH
Outline dimension 
159*97*38mm CASE:901
Weight 
0.5Kgs
Safety standards 
Satisfy UL1012,TUV EN60950  
EMC Standards 
------------
Note: 
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH Humidity.
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uFcapacitor circuit.
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage.
5.Load stability test: the load from 0% to 100%.

 

Drawing: