Product Show

Location:Home >> Products >> Switching Power Supply Series

S-201

Switching Power Supply Series
Keywords:
201w switch power supplies
Product Details

Model
Performance
S-201-5
S-201-7.5
S-201-12
S-201-13.5
S-201-15
S-201-24
S-201-27
S-201-48
DC output voltage
5V
7.5V
12V
13.5V
15V
24V
27V
48V
Output voltage tolerance(Note 2)
±2%
±2%
±1%
±1%
±1%
±1%
±1%
±1%
Rated output current
40A
26.5A
16.5A
14.7A
13A
8.3A
7.4A
4.2A
Output current range
0-40A
0-26.5A
0-16.5A
0-14.7A
0-13A
0-8.3A
0-7.4A
0-4.2A
Ripple and noise(Note 3)(注3)
150mVp-p
150mVp-p
150mV
150mV
150mV
150mV
200mV
240mV
Inlet stability(Note 4)
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
Load stability(Note 5)
±1%
±1%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
±0.5%
DC output power
200W
198.75W
198W
198.45W
198W
199.2W
199.8W
201.6W
Efficiency
74%
79%
80%
80%
81%
83%
83%
84%
DC voltage adjustable range
4.5-5.6V
6-9V
10-13.2V
12-15V
13.5-18V
20-26.4V
26-32V
41-56V
Input voltage range
90~132VAC/186~264VAC selected by switch 
47~63Hz;254~370VDC
Input current
4.5A/115V 2.5A/230V
Surge Current
25A/115V 50A/230V
Leakage Current
<3.5mA/240VAC
Overload protection
105%~150%type:pulsing hiccup shutdown Reset:Automatic recovery
over-voltage protection
5.75-6.75V
9.4-10.9V
13.8-16.2V
15.5-18.2V
18-21V
27.6-32.4V
33.7-39.2V
                         57.6-67.2V
High temperature protection
RTH3>=90℃ OUTPUT SHUTDOWN
temperature coefficient
±0.03%℃(0~50℃)
Start-up,rise,hold up time
200ms,100ms,20ms
shock resistance
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes
Withstand voltage
Input and Output internal:1.5KvAC,input and enclosure:1.5KvAC,
output and enclosure:0.5KvAC
Insulation Resistance
Input and Output internal: input and enclosure,output and enclosure:
500VDC/100M Ohms
work Temperature/humidity  
-10℃~+60℃(Refer to output derating curve),20%~90%RH
-10℃~+60℃,20%~90%RH
storage temperature /humidity
-20℃~+85℃,10%~95%RH
Outline dimension
215*115*50mm CASE:912
Weight 
0.9Kgs
Safety standards 
Satisfy UL1950
EMC Standards EMC
Design refer to FCC Part15 J Part15J class A
Note: 
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH Humidity.
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uFcapacitor circuit. 
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage.
5.Load stability test: the load from 0% to 100%. 
6.C3,4,41 must remove.  

 

Drawing: