Product Show

Location:Home >> Products >> Switching Power Supply Series

S-240

Switching Power Supply Series
Keywords:
240w switching power supply
Product Details

Model
Performance
S-240-5
 
S-240-12
S-240-15
S-240-24
S-240-30
S-240-48
S-240-7.5
DC output voltage
5V
 
12V
15V
24V
30V
48V
7.5V
Output voltage tolerance(Note 2)
±2%
 
±1%
±1%
±1%
±1%
±1%
±2%
Rated output current
40A
 
18A
15A
10A
8A
5A
30A
Output current range
0-40A
 
0-18A
0-15A
0-10A
0-8A
0-5A
0-40A
Ripple and noise(Note 3)
150mVp-p
 
150mV
150mV
180mV
180mV
240mV
200mV
Inlet stability(Note 4)
±0.5%
 
±0.5%
±0.5%
±0.5%
±0.5%
±1%
±0.5%
Load stability(Note 5)
±1%
 
±0.5%
±0.5%
±0.5%
±0.5%
±1%
±1%
DC output power
200W
 
216W
225W
240W
240W
240W
225W
Efficiency
78%
 
82%
83%
84%
85%
87%
80%
DC voltage adjustable range
4.5-5.8V
 
12-15V
13.5-18V
20-28V
27-33V
41-56V
6-9V
Input voltage range
88~132VAC/176~264VAC selected by switch 47~63Hz 47~63Hz;248~370VDC
 
Input current
5A/115V   2.5A/230V
 
Surge Current
Cold-start current:18A/115V 36A/230V
 
Leakage Current
<3.5mA/240VAC
 
Overload protection
105%-135%type:pulsing hiccup shutdown Reset:Automatic recovery
 
over-voltage protection
 105%-135%type:pulsing hiccup shutdown Reset:Automatic recovery
High temperature protection
PR1>=40℃ FAN ON. <35℃ FAN OFF.>=70℃ cut off output
 
temperature coefficient
±0.03%℃(0~50℃)
 
Start-up,rise,hold up time
100ms,500ms,30ms
 
shock resistance
10~500Hz,2G 10min./1circle,Period for 60min.,Each axes 
 
Withstand voltage
Input and Output internal:3KvAC,input and enclosure:1.5KvAC,
output and enclosure:0.5KvAC
 
Insulation Resistance
Input and Output internal: input and enclosure,output and 
enclosure:500VDC/100M Ohms
 
work Temperature/humidity  
-10℃~+50℃,20%~90%RH
 
storage temperature /humidity
-20℃~+85℃,10%~95%RH
 
Outline dimension
190*93*65mm 
 
Weight 
1.1Kgs
 
Safety standards
Satisfy UL1950 EN60950 
 
EMC Standards
EN55022,IEC1000-42,3,4,5  IEC10003-2,3
 
Note: 
1.The above parameters test conditions: 230VAC input, rated load, 25 ℃ 70% RH Humidity.
2.Tolerance: includes set up tolerance, line stability and load stability (Note 5).
3.The ripple test: 20MHz with A12 "twisted pair, interrupted with a 0.1uF & 47uFcapacitor circuit.
4.The incoming line voltage stability test: the minimum full load voltage of the incoming line to the highest voltage.
5.Load stability test: the load from 0% to 100%.
6.C3,4,41must remove. 

 